Tektronix RFM151 SignalScout DV3 Signal Level Meter
5 to 1080 MHz Frequency Range
The RFM151 provides all of the basic signal level easurement capabilities, and it also adds new spectrum analysis, ingress, and digital channel RF measurement capabilities not available in comparable products!
Includes Carrying Case & Accessories As Listed Above!
Working Condition: Excellent
Condition: Refurbished
Calibrated: Yes
Warranty: 1 YEAR WARRANTY
Tektronix RFM151 SignalScout CATV Meter
The SignalScout RFM151 is a high-performance RF measurement field tool tailored for analog/digital Cable TV networks. It is designed to meet the demanding requirements of cable television technicians performing troubleshooting and maintenance operations anywhere in the network. The RFM151 provides all of the basic signal level easurement capabilities, and it also adds new spectrum analysis, ingress, and digital channel RF measurement capabilities not available in comparable products!
Features:
Digital Channel RF Measurement Suite Includes Average Power Level Plus Noise/Distortion Measurement
Exclusive Ingress Monitor Mode Records Ingress Violations of up to 32 User-defined Frequency and Level Windows
Enhanced Spectrum Mode Increases Ability to Capture Lowlevel and Bursty Signals
AM and FM Demodulators with Speaker Helps Identify Ingress Sources
User-changeable Battery Pack with Optional External Charger for Uninterrupted Use
CSS151 Control and Analysis Software Includes Ingress/Spectrum Analysis Capability and Report Generation
Digital Channel Average Power
The RFM151’s stepped integration method efficiently and accurately delivers the true average power of QAM, QPR, QPSK, or VSB digital channels. Unlike single-point measure and calculate methods, the stepped integration technique takes into account signal abnormalities such as un-flatness.
The Peak Analog-to-Digital Average Power Level Difference measurement makes short work of verifying power loading in mixed analog and digital systems. Use it to set digital modulator levels referenced to the analog carriers.
Digital In-Channel Noise
With analog signals, carrier-to-noise ratios are important to picture quality. A similar measurement for digital signals is the Desired-to- Undesired Signal Ratio. This is an in-channel (out of service) average power-to-noise measurement that includes noise, as well as distortion signals, such as ingress and analog system-generated CSO and CTB.
Enhanced Spectral Analysis
The RFM151’s Spectrum Mode is an easy-to-use spectrum analysis tool that allows technicians to troubleshoot most problems before calling for more advanced equipment. Spectrum Mode Features include:
AM and FM demodulators
Dual markers
Noise marker
Window Sweep™
Max hold
Preamp control
Peak/average detection
Combination AM/FM demodulators with amplifier and speaker, are available both in Meter Mode and Spectrum Mode. These detectors help the technician identify both wanted signals, such as aural carriers, and unwanted signals, such as a two-way radio transmission, and other ingress.
The General Purpose Spectrum Mode offers a choice of no markers, dual frequency-amplitude markers with D readout, or noise markers (in dB/Hz) with selectable normalized bandwidth. Other features of spectrum mode include: Window Sweep which reduces the amount of swept display, increasing the display update rate to show rapidly changing signals; Max Hold, to show only the highest value of the displayed spectrum; Selectable Peak or Average detection modes, and a preamp for making ow-level readings.
Ingress Troubleshooting
The RFM151 is the technician’s best friend when it comes to troubleshooting ingress problems. Exclusive circuitry minimizes forward-path signals overloading the RFM151’s input when measuring return-path traffic. This means that low-level ingress measurements can be taken in common path locations – such as a tap or seizure screw. Add to this the quick scan rate of Window Sweep, max hold, peak detect, demodulation, field strength, and preamp controls and the RFM151 is able to measure return-path bursty signals and low-level ingress down to –65 dBmV (–5dBmV) to help locate the source (see Figure 2).
Ingress Monitoring
Another unique RFM151 feature is the Ingress Monitor Mode which allows up to 32 frequency windows to be defined within the displayed spectrum, each with its own level threshold (see Figure 3). When a signal violates the threshold, the instrument either stops and shows the display, stores the violation in memory, or continues. Violations can be stored as frequency/amplitude/time data, or complete spectrum displays with time stamps. Sweep delays can be set from 2 to 60 minutes in one-minute intervals allowing unattended monitoring.
Level Measurement
The SignalScout provides five different level displays: Single Channel, 5-channel, Pilots, All Channels, and Meter. These display modes can show either analog or digital channel information.
The 5-channel display mode provides both a numerical reading and a bargraph display. This is great for doing system-at-a-glance measurements and looking at tilt. The Pilots display mode shows both bargraph and numeric displays of any two frequencies used for setting the AGC in the plant.
Measurement Modes
The RFM151 also performs the following measurements: Carrier-to-Noise, Hum, FM Deviation, and Field Strength. Carrier-to-Noise can be configured for either In-Service (using the guard band) or Out-of-Service (with a user-settable frequency offset). Both measurements are normalized to the proper bandwidth for the system (4MHz for NTSC and 5MHz for PAL).
The Relative Field Strength mode allows the user to select a frequency between 5 and 1080MHz and use an optional antenna to locate the signal of interest. Field Strength Mode is useful for finding leaks in the cable plant and locating the sources (see Figure 4).
Worldwide Compatibility
The RFM151 works on any world television standard and all common transmission standards. It automatically measures the average power of a NICAM sound carrier. Just enter the correct frequency into the second aural carrier slot and the RFM151 does the rest.
Customized Settings – Time-Saving Measurement Sequences
The RFM151 and CSS151 Software form a powerful tool tailored to an individual cable system. By creating automatic test sequences using the CSS151 software, test time and errors are reduced. Tests can be setup to run at fixed time intervals using the interval timer in the RFM151, or under technician control. These sequences can be used for the FCC required tests including the 24-Hour test, or just for routine maintenance.
Report Generation
Data in the worksheet can be printed directly, or processed into concise reports for hard copy files. Reports include a Status Report that shows how well the system is performing with regard to level differences between adjacent channels and minimum and maximum level differences. Another report shows the visual carrier level and visual-to-aural carrier difference over four six-hour time periods for monitoring system performance over time and temperature. Both reports can be printed with up to six lines of header text for displaying additional information.
RF INPUT
Input Impedance – 75 W (nominal).
Connector Type – Male type F with precision female-to-female F
coupler.
FREQUENCY
Range – 5 to 1080 MHz.
Accuracy – +5 kHz or +10–5 of tuned frequency,
which ever is greater.
ANALOG AND DIGITAL LEVEL MEASUREMENTS
Sensitivity – –35 to 60 dBmV (+25 to +120 dB?V).
Repeatability – +0.5 dB.
DIGITAL TO ANALOG CARRIER DIFFERENCE
Analog Channel Select Mode – Automatic or user selectable.
Accuracy – ±2 dB.
IN BAND CARRIER TO NOISE
Measurement Location – User selectable.
Accuracy – ±2 dB.
Range – Up to 51 dB with carrier amplitude >5 dBmV,
modulation removed.
GUARD BAND CARRIER TO NOISE
Measurement Location – Guard band
(»1.25 MHz below the visual carrier).
Accuracy – ±2 dB.
Range – Up to 47 dB with carrier amplitude >0 dBmV.
DESIRED TO UNDESIRED
Measurement Location – In channel (Out of Service).
Accuracy – ±2%.
HUM
Fundamental Frequency – 50/60 Hz,
user-selectable frequency.
Range – 0 to 5%.
Accuracy – ±1%.
FM DEVIATION
Accuracy – ±10% of peak deviation or
±2kHz whichever is greater.
SPECTRUM MODES
Modes –
General Purpose (Dual/Noise/No markers).
Demod (AM, FM detectors, speaker).
Ingress Monitor
(up to 32 user-defined thresholds within a displayed spectrum).
Common Specifications –
Frequency Range: 5 to 1080 MHz.
Span/Division: 4 MHz, 2 MHz, 1 MHz, 400 kHz, 200kHz.
Resolution Bandwidth:
Span 1 MHz: 300 kHz.­­
Span <1MHz: 30kHz.
Sensitivity: –60 dBmV (–65 dBmV typical).­­­
Spurious Free Dynamic Range:
20 to 1080 MHz: –50 dBc.
5 to 20 MHz: £–40 dBc.
Detection Mode: Peak or Average.
Vertical Scales: 2, 5, 10, 15 dB/Div.
Other Controls: Preamp, Max Hold.
ENVIRONMENTAL
Temperature –
Operating: 0 to +50° C (+32 to +122° F).
Non-operating: –20 to +60° C
(–4 to +140°F).
Humidity –
Operating: 5 to 95% from 0 to +50° C.
Altitude –
Operating: Up to 15,000 ft. (4,550 m).
Non-operating: Up to 40,000 ft. (12,192 m).
POWER
DC Input Range – +10 to +15 VDC.
Power Requirement – 10 W maximum.
Battery Type – User replaceable.
Battery Life – 2.75 Hr.
Please check our Huge Inventory with savings of up to 80% off of retail on Cat5/5e/6 LAN Cable Certifiers and Fiber Optic OTDR's, Fusion Splicers, CATV Meters, Fiber Optic Kits, Sources, Meters, Tools, Network Analyzers and much more. Here is a Link to our
Ebay Test Equipment Store
. All of our Test Equipment is backed with a Full Warranty and unbeatable customer support & service. Please don't hesitate to
contact us
for a Quote on Something you don't see in our inventory, sometimes we have items that may have not been listed or processed yet.
Test Equipment Store Offers a wide range of Refurbished Telecom/ Datacom Tools and Test Measurement Equipment. Which includes Fiber Optic Test and Splicing tools, Fusion Splicers, OTDRs, Copper and Fiber Cable Certifiers, CATV Test Equipment, Cable and Antenna Analyzers, Network Analyzers and much more!
We carry a large inventory of quality refurbished and used test equipment from all the major manufacturers. If you are looking for multiple quantities or if we don't have a listing for a particular item that you are looking for. Please contact us as it may be fresh inventory waiting to be listed or we'll be glad to find it for you at the best price possible and put up an eBay listing for you!
We Ship World Wide!
We will attempt to ship your item(s) within 24 hours after payment has been received. To get a real-time shipping quote to your destination, enter your country and zip / postal code information into the shipping calculator and click "Get Rate".
Many countries impose their own customs, duties, tariffs, taxes, etc. on items being shipped from a foreign country. We do not cover those cost's and we recommend that you contact your countries customs agency for that information.
We Offer Multiple Quantity Price & Shipping Discounts, Email Us If You Are Interested In Larger Quantities.
We accept credit card payment transactions via the online checkout system! The checkout process is designed so that it communicates with the merchant to confirm that payment has been made and cleared. Other methods of payment are outlined through the online checkout process. Winning bidders must contact us within 3 days after auction close if special payment arrangements are needed.
Your payment is expected within 5 days after the auction close. Unpaid auctions will be forfeited after 5 days of the auction close and the Item(s) will be relisted for sale.
Items will be shipped within 24 hours (1 Business Day) upon receipt of payment from the winning bidder. (Certain orders may take longer for processing due to comprehensive final service inspections)
A Shipment Tracking number(s) will be provided to inform Buyers of their expected ETA (Estimated Time of Arrival). Tracking number(s) will be provided the same day as order shipment.
Thank you
ALL MAJOR CREDIT CARDS & PayPal ACCEPTED
Sell Smarter with
Kyozou
.
Inventory and Ecommerce Management