-40%

Fluke 1738 Advanced Three-Phase Power Logger with current probes

$ 3303.69

Availability: 54 in stock
  • MPN: 1738
  • Refund will be given as: Money back or replacement (buyer's choice)
  • All returns accepted: Returns Accepted
  • Brand: Fluke
  • Condition: New
  • Return shipping will be paid by: Seller
  • Item must be returned within: 30 Days

    Description

    Untitled Document
    Fluke 1738 Advanced Three-Phase Power Logger with current probes
    Model:
    1738
    | Order No:
    1738/EUS
    Conduct energy studies and power quality logging with this advanced three-phase power logger. This product automatically captures and logs over 500 power quality parameters providing you with more visibility into the data. Additionally, this unit is Fluke Connect compatible and comes equipped with current probes.
    Brand:
    Fluke
    Model:
    1738
    Order No:
    1738/EUS
    Condition:
    NEW
    Description
    Fluke 1738 Advanced Three-Phase Power Logger with current probes
    More visibility, reduced uncertainty and better power quality and energy consumption decisions
    Compatible with the Fluke Connect® mobile app and desktop software, this unit provides you the data required for you to make critical power quality and energy decisions in real-time. Ideal for conducting energy studies and basic power quality logging, this automatically captures and logs over 500 power quality parameters, giving you more visibility into the data you need to optimize system reliability and savings.
    Features an optimized user interface and an intelligent measurement verification function that enables you to decrease measurement errors by digitally verifying and correcting common connection errors makes setup easier and reduces measurement uncertainty. Access and share data remotely with your team via the Fluke Connect® app so you can maintain safer working distances and make critical decisions in real-time, reducing the need for protective equipment, site visits, and check-ins. You can also quickly and easily chart and graph measurements to help identify issues and create detailed reports with the included Energy Analyze Plus software package.
    Features
    Measure all three phases and neutral
    with 4 flexible current probes (sold separately)
    Comprehensive logging:
    More than 20 separate logging sessions can be stored on the instruments. In fact, all measured values are automatically logged so you never loose measurement trends. They can even be reviewed during logging sessions and before downloading for real-time analysis
    Capture dips, swells, and inrush currents:
    includes event waveform snapshot and high resolution RMS profile, along with date, timestamp and severity to help pinpoint potential root causes of power quality issues
    Bright, color touch screen:
    Perform convenient in-the-field analysis and data checks with full graphical display
    Optimized user interface:
    Capture the right data every time with quick, guided, graphical setup and reduce uncertainty about your connections with the intelligent verification function
    Fully integrated logging:
    Connect other Fluke Connect devices to this product to simultaneously log up to two other measurement parameters
    Energy Analyze Plus application software:
    Download and analyze every detail of energy consumption and power quality state of health with our automated reporting
    Present data locally on the logger, on the Fluke Connect mobile app and desktop software, or through your facility's Wi-Fi infrastructure
    Power the instrument directly from the measured circuit
    Review measured values during logging sessions and before downloading for real-time analysis
    Event waveform snapshot and high-resolution RMS profile, along with date, timestamp and severity to capture dips, swells, and inrush currents and help pinpoint potential root causes of power quality issues
    Provides fast insight into overall electrical system health with a Power Quality Health Summary
    Offers a bright, color touch-screen display for convenient field analysis and data checks
    Helps you capture the right data every time with a quick, guided, graphical user interface
    Reduces uncertainty about your connections with the intelligent verification function
    Allows you to complete field setups through the front panel or the Fluke Connect App on your smartphone
    Energy Analyze Plus application software that enables you to analyze every detail of energy consumption and power quality health and create automated reports
    Easy to use
    The four current probes are connected separately; the instrument automatically detects and scales the probes. The thin current probes are designed to easily get through tight conductor spacing and are easily set to 150 or 1500 A for high accuracy in nearly any application. An innovative tangle-free flat voltage lead makes connection simple and reliable and the instrument's intelligent ‘Verify Connection' feature automatically checks to make sure the instrument is connected correctly and can digitally correct common connection issues without having to disconnect measurement leads.
    The detachable power supply can be conveniently and safely powered directly from the measured circuit—no more searching for power outlets or having to run multiple extension cords to the logging location.
    Data downloading couldn't be easier or more flexible:
    Download directly to a USB flash drive that plugs directly into the USB port of the instrument
    View measurements remotely via the Fluke Connect mobile app and desktop software, helping you maintain safer working distances and reducing the need for personal protective equipment and unnecessary site visits and check-ins
    Analysis and Reporting
    Capturing logged data is just one part of the task. Once you have the data, you need to create useful information and reports that can be easily shared and understood by your organization or customers. Fluke Energy Analyze Plus software makes that task as simple as possible. With powerful analysis tools and the ability to create customized reports in minutes you'll be able to communicate your findings and quickly solve problems so you can optimize system reliability and savings.
    Applications
    Load studies:
    verify electrical system capacity before adding loads
    Energy assessments:
    quantify energy consumption before, and after improvements, to justify energy saving devices
    Harmonics measurements:
    uncover harmonic issues that can damage or disrupt critical equipment
    Voltage and current event capture:
    monitor for dips, swells and inrush currents that cause false resets or nuisance circuit breaker tripping
    Log the most common parameters
    Designed to measure the most critical three-phase power parameters, this instrument can simultaneously log RMS voltage, RMS current, voltage, current events, and current THD, voltage and current harmonics up to the 50th harmonic, active power, reactive power, power factor, active energy, reactive energy, and more. With enough memory for more than a year of data logging, this power logger can uncover intermittent or hard-to-find issues that might otherwise have been missed.
    Included
    Power Logger
    Voltage Test Leads
    4 x Alligator Clips
    4 x Flexible Current Probes
    Magnetic Hanging Strap
    4 x Magnetic Voltage Probes
    Line Cords
    Color Coding Set
    Carrying Case
    Power Supply
    WiFi/BLE Adapter
    Specifications
    Accuracy
    Voltage
    Range: 1000 V
    Maximum resolution: 0.1 V
    Intrinsic accuracy at reference conditions (% of reading + % of full scale): ±(0.2% + 0.01%)
    Frequency
    Range: 42.5 to 69 Hz
    Maximum resolution: 0.01 Hz
    Intrinsic accuracy at reference conditions (% of reading + % of full scale): ±(0.1%)
    Aux Input
    Range: ±10 V dc
    Maximum resolution: 0.1 mV
    Intrinsic accuracy at reference conditions (% of reading + % of full scale): ±(0.2% + 0.02%)
    Voltage Min/Max
    Range: 1000 V
    Maximum resolution: 0.1 V
    Intrinsic accuracy at reference conditions (% of reading + % of full scale): ±(1% + 0.1%)
    Current Min/Max
    Range: Defined by accessory
    Maximum resolution: Defined by accessory
    Intrinsic accuracy at reference conditions (% of reading + % of full scale): ±(5% + 0.2%)
    THD on Voltage
    Range: 1000%
    Maximum resolution: 0.1%
    Intrinsic accuracy at reference conditions (% of reading + % of full scale): ±0.5
    THD on Current
    Range: 1000%
    Maximum resolution: 0.1%
    Intrinsic accuracy at reference conditions (% of reading + % of full scale): ±0.5
    Voltage Harmonics 2nd ...50th
    Range: 1000 V
    Maximum resolution: 0.1 V
    Intrinsic accuracy at reference conditions (% of reading + % of full scale): ≥10 V: ±5% of reading, <10 V: ±0.5 V
    Current Harmonics 2nd ...50th
    Range: Defined by accessory
    Maximum resolution: Defined by accessory
    Intrinsic accuracy at reference conditions (% of reading + % of full scale): ≥3% of current range: ±5% of reading, <3% of current range: ±0.15% of range
    Unbalance
    Range: 100%
    Maximum resolution: 0.1%
    Intrinsic accuracy at reference conditions (% of reading + % of full scale): ±0.2
    Power Supply
    Voltage Range
    100 to 500 V using safety plug input when powering from the measurement circuit
    100 to 240 V using standard power cord (IEC 60320 C7)
    Power Consumption
    Maximum 50 VA (max. 15 VA when powered using IEC 60320 input)
    Efficiency
    ≥68.2% (in accordance with energy efficiency regulations)
    Maximum No-Load Consumption
    <0.3 W only when powered using IEC 60320 input
    Mains Power Frequency
    50/60 Hz ± 15%
    Battery
    Li-ion 3.7 V, 9.25 Wh, customer-replaceable
    On-Battery Runtime
    Four hours in standard operating mode, up to 5.5 hours in power saving mode
    Charging Time
    <6 hours
    Data Acquisition
    Resolution
    16-bit synchronous sampling
    Sampling Frequency
    10.24 kHz at 50/60 Hz, synchronized to mains frequency
    Input Signal Frequency
    50/60 Hz (42.5 to 69 Hz)
    Circuit Types
    1-ø, 1-ø IT, split phase, 3-ø delta, 3-ø wye, 3-ø wye IT, 3-ø wye balanced, 3-ø Aron/Blondel (2-element delta), 3-ø delta open leg, currents only (load studies)
    Data Storage
    Internal flash memory (not user replaceable)
    Memory Size
    Typical 10 logging sessions of 8 weeks with 1-minute intervals and 500 events
    Basic Interval
    Measured Parameters
    Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy
    Averaging Interval
    User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
    Averaging Time Min/Max Values
    Voltage, Current: Full cycle RMS updated every half cycle (URMS1/2 according to IEC61000-4-30)
    Aux, Power: 200ms
    Demand Interval (Energy Meter Mode)
    Measured Parameters
    Energy (Wh, varh, VAh), PF, maximum demand, cost of energy
    Interval
    User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off
    Power Quality Measurements
    Measured Parameter
    Voltage, frequency, unbalance, voltage harmonics, THD V, current, harmonics, THD A, TDD
    Averaging Interval
    10 min
    Individual Harmonics
    2nd ...50th harmonic
    Total Harmonic Distortion
    Calculated on 50 harmonics
    Events
    Voltage: dips, swells, interruptions, current: inrush current
    Triggered Recordings
    Full cycle RMS updated every half cycle of voltage and current (Urms1/2 according to IEC61000-4-30)
    Waveform of voltage and current
    Standards Compliance
    Harmonics
    IEC 61000-4-7: Class 1
    IEEE 519 (short time harmonics)
    Power Quality
    IEC 61000-4-30 Class S, IEC62586-1 (PQI-S device)
    Power
    IEEE 1459
    Power Quality Compliance
    EN50160 (for measured parameters)
    Interfaces
    USB-A
    File transfer via USB flash drive, firmware updates, max. supply current: 120 mA
    WiFi
    File transfer and remote control via direct connection or WiFi infrastructure
    Bluetooth
    Read auxiliary measurement data from Fluke Connect® 3000 series modules (requires 1738, or 1736 upgrade option)
    USB-Mini
    Data download device to PC
    Voltage Inputs
    Number of Inputs
    4 (3 phases and neutral)
    Maximum Input Voltage
    1000 Vrms, CF 1.7
    Input Impedance
    10 M&ohm
    Bandwidth
    42.5 Hz to 3.5 kHz
    Scaling
    1:1 and variable
    Measurement Category
    1000 V CAT III/600 V CAT IV
    Current Inputs
    Number of Inputs
    4, mode selected automatically for attached sensor
    Input Voltage
    Clamp input: 500/50 mVrms; CF 2.8
    Rogowski Coil Input
    150/15 mVrms at 50 Hz, 180/18 mVrms at 60 Hz; CF 4; all at nominal probe range
    Range
    1 to 150/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12"
    3 to 300/30 A to 3000 A with thin flexible current probe i17XX-flex3000 24"
    6 to 600/60 A to 6000 A with thin flexible current probe i17XX-flex6000 36"
    40 mA to 4/0.4 A to 40 A with 40 A clamp i40s-EL
    Bandwidth
    42.5 Hz to 3.5 kHz
    Scaling
    1:1 and variable
    Auxiliary Inputs
    Number of Inputs
    2
    Input Range
    0 to ±10 V dc, 1 reading/s
    Scale Factor
    Format: mx + b (gain and offset) user configurable
    Displayed Units
    User configurable (7 characters, for example, °C, psi, or m/s)
    Wireless Connection
    Number of Inputs
    2
    Supported Modules
    Fluke Connect® 3000 series
    Acquisition
    1 reading/s
    Environmental Specifications
    Operating Temperature
    14 to 122°F (-10 to 50°C)
    Storage Temperature
    −4 to 140°F (-20 to 60°C)
    With battery: −4 to 122°F (-20 to 50°C)
    Operating Humidity
    50 to 86°F (10 to 30°C) max. 95% RH
    86 to 104°F (30 to 40°C) max. 75% RH
    104 to 122°F (40 to 50°C) max. 45% RH
    Operating Altitude
    6561.68' (2000 m) (up to 13123.36' (4000 m) derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)
    Storage Altitude
    39,370.079' (12,000 m)
    Enclosure
    IP50 in accordance with EN60529
    Vibration
    MIL-T-28800E, Type 3, Class III, Style B
    Safety
    IEC 61010-1
    IEC Mains Input: Overvoltage Category II, Pollution Degree 2
    Voltage Terminals: Overvoltage Category IV, Pollution Degree 2
    IEC 61010-2-031: CAT IV 600 V / CAT III 1000 V
    Electromagnetic Compatibility (EMC)
    EN 61326-1: Industrial CISPR 11: Group 1, Class A
    Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment)
    USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
    Temperature Coefficient
    0.1 x accuracy specification/°C
    General Specifications
    Color LCD Display
    4.3" (109.22 mm) active matrix TFT, 480 pixels x 272 pixels, resistive touch panel
    Tamper Protection
    Kensington lock slot
    Dimensions
    Instrument: 7.8 x 6.6 x 2.2" (19.8 x 16.7 x 5.5 cm)
    Power supply: 5.1 x 5.1 x 1.8" (13.0 x 13.0 x 4.5 cm)
    Instrument with power supply attached: 7.8 x 6.6 x 3.5" (19.8 x 16.7 x 9 cm)
    Weight
    Instrument: 2.5 lb (1.1 kg)
    Power supply: 0.9 lb (400 g)
    Terms & Conditions
    Item Condition:
    Unless specified otherwise all products listed are Brand New in the original factory packaging and include a full factory warranty.
    Shipping:
    We currently only ship to U.S. buyers. We ship items within one or two business days from payment. We do not process shipments on weekends and holidays. Local pick up is not available. We only ship to addresses verifiable by either PayPal or credit card issuing bank.
    Please note that we cannot alter the address once a purchase is made. In the case of PayPal payment, we will ship orders when the payment is marked “Eligible” for PayPal Seller’s protection.
    *Shipping Rates are for Continental US, Please Contact us for other US Destinations
    Payment:
    Currently all payments must be made directly though PayPal
    Sales Tax:
    We are required to charge sales tax in North Carolina
    Return Policy:
    If for any reason you are not 100% satisfied with a product you receive from us, you may return the regular stock product within 30 days from the time of receipt, for a full refund or exchange of the product you purchased (less any shipping costs). Within this time, products may be returned; freight prepaid and must be in their original packaging and in resalable condition.
    Shipping errors, missing items or damages must be reported to us immediately (damages should be accompanied by a signed bill of lading acknowledging the damage). Items returned will be inspected for damage or misuse at which time they may be subject to restocking fees, other fees or refused, prior to the issuance of any credit.